The Purpose of Vacuum Oven is to provide heating under vacuum condition or in some inert atmosphere to stop oxidising the product. Analysis Make GMP vacuum oven are especially built to Pass FDA and ICH Q1A compliance standards and have a reputation for reliability, quality and performance. Exceed FDA/ICH guidelines for long term , intermediate and accelerated stability studies.

Vacuum Oven Equipments

Specification :

Temperature Range 5.0 °C above ambient to 250.0 °C. Accuracy +/- 0.5 °C. Uniformity +/- 1.0 °C

 Temperature Display : Digital LED 3 ½ digit, Resolution 0.1 deg C

 Heating system: Heating coil mounted on fibre glass cloth wounded on the chamber.

 Two Valve Provided to do vacuum or inert atmosphere.

Construction :

Double walled , gap between walls filled with glasswool Insulation.

 Standard Model : Stainless steel Mirror polished chamber and heavy guage Powder- coated CRC exterior.

 GMP Model : Stainless steel Mirror polished chamber and exterior of dull finish stainless steel.

 Glass door : Front door mounted with glass door for Full observation of the chamber.

 3” Thick glasswool Insulation.

 Stainless steel Trays. Adjustable Tray Height adjustment.

 Unit Mounted on castor wheels with front lock arrangement for hamco106e and above model.

Control Panel: :

Microprocessor based PID temp. controller with auto tune facility for precise control of temperature.

 Temp. Sensor : PT- 100.

 Dedicated safety thermostatic controller to cut off the supply in case of overshoot of temperature.

 Recorder data bank to store and print set values , process values , date and time of master controllers with variable print time intervals ( Optional)

 Alarm : Audio visual alarm if temperature deviates from the preset temperature.

 PC Interface communication card with RS 485 for temperature control system ( Hardware only) ( optional)

 

Safety Features:

Over heat temperature cut off with alarm.

 Electrical short circuit breaker.

 Three heat switch to reduce the heater capacity for low temperature Option.

 

Data Record:

 21 CFR Part 11 compliant software with audit trial ( who did what and when is recorded)

 Multilevel Passwords.

 Data storage device has online and offline capabilities.

 Multi chamber data acquisition on single software.

 Tabular and graphical report, alarm deviation report.

 Mean Kinetic temperature report and alarm deviation report.

 Audit trial report.

 Attractive reports and graphs.

 Alarm report.

 Time synchronisation.